Ultra Low Temperature Cold Rooms

Walk-in storage rooms that hold set points down to −80 °C with tight uniformity, for vaccines, biologics and biobank samples.

−90°C0°C+300°C
−80°CUltra Low Temperature Cold Rooms
Ultra Low Temperature Cold Rooms by ESKIMO HVAC
Overview

How it works

Our ULT cold rooms give you freezer-grade temperatures at room scale. Each room is built around a cascade or two-stage refrigeration package sized to your load, so the space recovers fast after door openings and holds its set point through the night.

Panels use high-density PUF insulation with thermal-break joints and heated door frames, so ice doesn't build up at the seals. Controls log every reading and raise alarms by SMS and email, and a standby refrigeration circuit can take over automatically if the duty unit trips.

Key features

Down to −80 °C

Cascade refrigeration holds deep set points at room scale, not cabinet scale.

±1 °C uniformity

Air distribution is designed and mapped so every shelf sees the same temperature.

Duty + standby

Redundant refrigeration circuits with automatic changeover on fault.

Continuous logging

Data logger with audit trail, alarm history and exportable reports.

Heated door frames

Frame heaters and pressure-relief ports stop frosting and door suction.

Energy-optimised

EC fans, electronic expansion valves and smart defrost cut running cost.

Technical specifications

Typical specification

Temperature range−40 °C to −80 °C
Uniformity±1 °C to ±2 °C (mapped)
Insulation150–200 mm PUF panels, 40–42 kg/m³
RefrigerationCascade / two-stage, duty + standby
ControlsPLC/HMI with data logger, SMS & email alarms
Room sizesCustom, from 10 m³ upward

Every system is custom-engineered. Final capacities and specifications are confirmed in our proposal for your project.

Applications

Where it's used

  • Vaccine & biologics storage
  • Biobanks & sample repositories
  • Research institutes
  • Plasma & blood products
  • Specialty chemicals
FAQ

Common questions

How long does a −80 °C room take to pull down?

Pull-down time depends on room volume and the refrigeration package. We size the system to your target and state the expected pull-down time in the proposal.

Can you validate the room for GMP use?

Yes. We provide temperature mapping, calibration certificates and IQ/OQ documentation on request.

What happens if a compressor fails?

Rooms can be built with a standby circuit that starts automatically, and the alarm system notifies your team at the same time.

Related products

You may also need

−80°CLow Temperature Chillers
Low Temperature Chillers by ESKIMO HVAC
+5 °C to −80 °C

Low Temperature Chillers

Brine and glycol chillers that deliver steady low-temperature fluid for process cooling, reactors and lab work.

−90°C0°C+300°C
Brine ChillersProcess ChillersLab & R&D
View product
−80°C / +300°CSingle Fluid Thermal Control System
Single Fluid Thermal Control System by ESKIMO HVAC
−80 °C to +300 °C

Single Fluid Thermal Control System

One circulating fluid loop that heats to +300 °C and cools to −80 °C on the same skid, for reactor jackets and process vessels.

−90°C0°C+300°C
TCUReactor ControlHeating & Cooling
View product
−30°CLow Temperature Cold Rooms
Low Temperature Cold Rooms by ESKIMO HVAC
+8 °C to −30 °C

Low Temperature Cold Rooms

Insulated cold rooms that hold stable chiller and freezer set points for bulk storage, distribution and cold chain.

−90°C0°C+300°C
Bulk StorageDistribution HubsCold Chain
View product

Need a customised cooling solution?

Tell our engineers about your process, from a single machine to a full production line. We reply with a spec and a quote, usually within a working day.